Sign In | Join Free | My burrillandco.com |
|
Ask Lasest Price | |
Brand Name : | Sansion Power |
Model Number : | SXVLF-80KV |
Certification : | ISO9001, SGS |
Price : | Negotiation |
Payment Terms : | L/C, T/T, Western Union |
Supply Ability : | 100 Sets Per Month |
30/40/50/60/70/80 kV Vlf Low Frequency Ac Hipot Test Set
General information:
VLF stands for Very Low Frequency. VLF is generally considered to
be 0.1 Hz and lower, its major application is for testing solid
dielectric cable, transformers, motors, generators, switchgear and
other electrical apparatus.
A VLF hipot is just an AC output tester but with an output
frequency of 0.1 Hz or lower rather than 50/60Hz. Although the
frequency is very low, it is still an alternating current with
polarity reversals every half cycle. At 0.1 Hz output, rather than
60Hz, it takes 600 times less current and power to apply an AC
voltage to a capacitive load, like a long cable.
Features:
√ Adapts microprocessor controlled, can realize voltage
set-up/down, measuring and protecting automatically. Manual
intervention is allowable even during the auto voltage boosting.
√ Portable, easy to move.
√ Large LCD can display waveform clearly, and test report can be
printed. Built-in printer.
√ The data of current, voltage, and waveform can be sampled at HV
side.
√ A high voltage output protective resistor is provided in the
voltage boost body in the design and this eliminates the need of
additional protective resistor connected outside.
√ Closed-loop negative feedback circuit is adopted. No capacity
rising during outputting.
√ Over voltage and current protection: When the output is beyond
the limitation, the control unit will shut itself down within 20ms.
Specifications:
√ Peak voltage: 80kV
√ Output frequency: 0.1Hz, 0.05Hz and 0.02 Hz (selectable)
√ Fuse: 20A
√ Maximum load capacity: 0.5μF@0.1Hz; 1.0μF@0.05Hz; 2.5μF@0.02Hz
√ Power supply: 220V ±10%, 50Hz ±5% (If using a portable generator,
make sure the output voltage and frequency are stable. Power
>3kW. Power supply @ 110V 60Hz is optional)
√ Output voltage accuracy: peak voltage instability ≤1%; frequency
instability ≤3%.
√ Voltage waveform distortion: ≤5%.
√ Working environment: indoor or outdoor; -10ºC-+50ºC; 85%RH.
√ Weight: Control unit - 4kg; HV unit I: 25kg; HV unit II: 45kg.
Remarks: Capacitance of test object cannot be larger than the
maximum value of the test instrument. If capacitance of test object
is smaller than 0.05μF, the hipot should be equipped with an
auxiliary device (supplied by Sansion Power Electric at your
option).
Please contact us for further information. Sansion Power has a
technically experienced expertise team to select correctly designed
test set for you.
![]() |